Categories
DESCRIPTION
Application
The Deltabar FMD71 is an electronic differential pressure (dp) measurement system designed to monitor the pressure, level, volume, or mass of liquids in pressurized tanks or distillation columns/evaporators. It uses two sensors: the high-pressure (HP) sensor to measure hydrostatic pressure and the low-pressure (LP) sensor to gauge head pressure. By processing these two digital readings, the transmitter calculates the liquid level. This electronic dp system addresses and overcomes the challenges posed by conventional mechanical differential pressure systems.
Ideal for measuring differential pressure, level, volume, or mass of liquids in pressurized tanks and distillation columns/evaporators.
Specifications:
- Process connections: Threads, flanges, and hygienic options
- Process temperature range: -40 to +150°C (-40 to +302°F)
- Measurement range: 100mbar to +40bar (6 to 600psi)
- Accuracy: ±0.05% for single sensors; ±0.07% for the system
- Certifications: International explosion protection and hygienic approvals
Benefits
- Eliminates mechanical issues typical of traditional systems, enhancing process reliability and availability.
- Features an overload-resistant, high-purity ceramic sensor (99.9% Al2O3).
- The electronic differential pressure system’s architecture minimizes safety risks.
- Lower total cost of ownership due to reduced installation time, maintenance, downtime, and fewer spare parts.
- Provides multivariable level measurement, offering HART-based data on differential pressure, head pressure, and sensor temperatures from a single system.
- Continuous health monitoring of the system is ensured via HART-based diagnostics.
- High reproducibility and long-term stability.